Accurate Ψ-value and psi calculations for Part L compliance

At Barlings KWA, we provide professional thermal bridging detail calculations to support SAP, SBEM, and Building Regulations compliance.

Thermal bridges occur at junctions where building elements meet, such as:

  • wall to floor junctions
  • wall to roof junctions
  • window jambs, heads and sills
  • lintels
  • corners

These junctions can significantly increase heat loss and condensation risk if not properly assessed.

Our detailed psi value calculations help demonstrate compliance with Building Regulations Part L while improving overall fabric performance.

What Are Thermal Bridging Calculations?

A thermal bridging calculation measures the additional heat loss at junctions in the building envelope.

This is expressed as a Ψ-value (psi value) in W/mK.

Unlike a U-value, which measures heat loss through an area, a psi value measures heat loss along a junction line.

Typical examples include:

  • where the external wall meets the ground floor
  • roof eaves details
  • window and door openings
  • steel beam penetrations
  • junctions around flat roof upstands

These values are then entered into SAP or SBEM calculations to improve the overall Y-value and energy performance result.

Why Are They Important?

Even when wall, roof, and floor U-values are good, poor junction details can create significant additional heat loss.

Thermal bridges may contribute a substantial proportion of total fabric heat loss and can also increase the risk of:

  • surface condensation
  • mould growth
  • cold spots
  • occupant discomfort

By calculating the junctions accurately, we can often improve the SAP result compared with default assumptions.

When Do You Need Them?

You may need thermal bridge calculations for:

  • new dwellings
  • extension details
  • commercial Part L projects
  • bespoke junction details
  • steel frame interfaces
  • retrofit insulation projects
  • SAP and SBEM compliance
  • condensation risk checks

This is especially useful where standard manufacturer details are not available.

Our Service Includes

At Barlings KWA, we provide:

  • bespoke junction psi calculations
  • linear thermal transmittance (Ψ) values
  • condensation temperature factor checks
  • SAP and SBEM compatible outputs
  • BR 497 compliant calculations
  • practical junction improvement advice
  • fast turnaround

Calculations are undertaken in accordance with BRE BR 497

Request a Quote

Need thermal bridging calculations for your project?

Contact Barlings KWA for a fast quotation and expert advice.

Email:william@barlingskwa.co.uk