Air Tightness Testing in Lincoln, Lincolnshire and the East Midlands
Professional Air Pressure Testing to Help Your Project Pass Building Regulations First Time
If you are building a new property or commercial building, Air Tightness Testing is required to demonstrate compliance with Building Regulations Part L.
At Barlings, we provide fast, reliable Air Pressure Testing across Lincoln, Lincolnshire and further afield, helping builders, developers and homeowners obtain the certification needed for Building Control approval.
We aim to make the process simple, quick and stress-free, with clear reports and practical advice if improvements are required.
Get in touch today for a quick quote.
Why Choose Barlings?

✔ Experienced in Building Regulations compliance
✔ Reliable and professional service
✔ Clear reports
✔ Practical advice to help projects pass first time
✔ Local Lincolnshire based service
We understand the pressures of construction projects and aim to provide a straightforward and dependable service you can rely on.
Our Air Testing Service
At Barlings, we provide a professional and efficient testing service designed to help your project progress smoothly.
Our service includes:
• Air pressure testing using calibrated equipment
• Experienced and qualified tester
• Clear results and advice if improvements are needed
• Fast turnaround of certification for Building Control
• Friendly and practical support throughout the process
We work with builders, developers, architects and homeowners across Lincolnshire.
The Air Testing Process
The test itself is straightforward and usually takes around 1 hour on site.
1. Equipment setup
A specialist fan is fitted into an external doorway and connected to measuring equipment.
2. Building pressurised

The fan increases and decreases the air pressure within the building.
3. Air leakage measured
Sensors measure how quickly air escapes through the building envelope.
4. Test results calculated
The air permeability rate is calculated and compared with the required standard.
5. Certificate issued
A formal test certificate is produced for submission to Building Control.
Common Causes of Air Test Failures
Most buildings pass without issue, but common areas that can cause air leakage include:
-
Air escaping behind plasterboard due to poorly installed board adhesive
-
Poorly sealed service penetrations
-
Gaps around windows and doors
-
Unsealed pipe penetrations
-
Open cavities or poorly sealed plasterboard
If any issues are identified during testing, we are happy to offer practical advice to help achieve compliance